KJS130V
KJS130V

Advanced Technology
 
Super 3 Series Diesel Engine
The Super 03 vertical, water-cooled, 4-cycle diesel engines ensure greater power, more efficient combustion, and cleaner emissions.
 
Quick Start-Ups
Super glow system comes as standard equipment to shorten preheating time and quicken engine start ups in cold temperature.
 
Low Noise and Vibration
Kubota's inherent low noise design, a sound attenuated enclosure which effectively reduced all sound including that of the muffler, and the original TVCS combustion system substantially reduced the sound levels. Integral vibrations were also reduced by inserting rubber pads and additional supporters in critical areas. As an option, Kubota offers an easy to attach noise reduction kit, the Soft Noise Kit, for people who need additional noise reduction.
 
Convenient Operation
All switches and lamps are conveniently located in the center of the front panel for maximum accessibility. Transportability is also an important factor. Twin point lifting eye made it easy to transport all KJ Series generators.
 
Stable Generation
All KJ Series generators are equipped with a transistor AVR (Automatic Voltage Regulator) to regulate a stable flow of current. Its convertible (50/60Hz) electronic regulator is powered independently from the voltage detection circuit, therefore regulation is not affected by distortions generated by the load.
 
Increased Safety
The automatic shutdown mechanism automatically stops the engine should a problem arise with the engine's oil pressure or water temperature. Automatic air bleeding automatically removes power robbing air-bubbles from the fuel line. Emergency relay, timer relay, and safety relay are gathered into one unit to save space, simplify the wiring scheme, and to improve protection against water, dust, and vibration. This unit also includes key stop and mechanical manual emergency stop mechanisms. All rotating generator parts have been enclosed in a metal enclosure for maximum operator safety. In addition, all output terminals have been gathered on the side to reduce cable entanglements.
 
Carefree Maintenance
Oil, fuel, water, and filters are all located on one side for easy maintenance. The battery pack, which is located in the rear of the generator, can be easily removed through the back panel.

Specifications
Model KJ-S130V KJ-S170F KJ-T130D KJ-T180V KJ-T230F
Generator
Type Revolving field, self-generating brushless AC generator Revolving field, self-generating brushless AC generator
Frequency (Hz) 50 50
Rated output (kVA/kW) 12.5/12.5 17.0/17.0 12.5/10.0 18.0/14.4 23.0/18.4
Number of phases 1 3
AC voltage (V) 220 110/220 120/240 220 110/220 120/240 220 380 415 220 380 415 220 380 415
Current (A) 56.8 56.8 52.1 72.3 72.3 70.8 32.8 19.0 17.4 47.2 27.3 25.0 60.4 34.9 32.0
Power factor (%) 100 80
Number of poles 4 4
Rating Continuous Continuous
Insulation class H H
Drive Direct drive Direct drive
Engine
Emergency stop system Vertical, water cooled, 4-cycle diesel engine Vertical, water-cooled, 4-cycle diesel engine
Model KUBOTA V2203 KUBOTA F2803 KUBOTA D1703 KUBOTA V2203 KUBOTA F2803
Number of cylinders 4 5 3 4 5
Bore stroke (mm) 87 x 92.4 87 x 92.4
Total displacement (mm) 2197 2746 1647 2197 2746
Revolutions (rpm) 1500 1500 1500 1500 1500
Continuous rated output (PS) 23.0 28.7 17.2 23.0 28.7
Lubricating oil API service class CC or CD 10W30 API service class CC or CD 10W30
Oil capacity (L) 8.7 10.5 6.3 8.7 10.5
Coolant capacity (L) 7.9 9.4 6.9 7.9 9.4
Set
Fuel DIESEL No.2 ( ASTM D975) DIESEL No.2 (ASTM D975)
Fuel tank capacity (L) 37 60 37 37 60
Fuel consumption (L/hr) 5.3 6.6 4.0 5.3 6.6
Starting method Electric Electric
Length (mm) 1488 1613 1393 1488 1613
Width (mm) 650 740 650 650 740
Height (mm) 970 995 970 970 995
Total dry weight (kg) 515 610 450 515 610
Battery capacity (Ah) 70 70 80
Emergency stop system In case of abnormal Oil Pressure or water temperature In case of abnormal Oil Pressure or water temperature
*Injury can occur: Do not connect generator to an electrical system unless an isolation switch has been installed, otherwise injury can occur.
*The company reserves the right to change specifications without notice to incorporate technological advances and engineering modifications.
*Thermostat kit is required for operation below -10 degrees Celsius.